We offer highly cost-effective products and professional after-sale service for the marine, HVAC, water, oil & gas, fire fighting industries. Our valves, all delivered by experienced technicians, are of guaranteed good quality.
> Water > HVAC > Marine > Oil & Gas > Industry > Fire FightingWith years of experience, I-FLOW knows the market very well. We can provide excellent one-stop solutions for our clients. For more information about our valves and service, contact us today!
> CEO'S Greeting > Our factory > Career & culture > Fairs and eventsI-FLOW has an excellent R&D team. Managed strictly under ISO 9001, we inspect and test each of our valves to make sure 100% qualified.
> Research & Development > Quality Control > Quality Assurance > CertificatesWe, together with our associated companies, have obtained various types of certificates, including CE, WRAS, DNV, GL, LR, ABS etc. I-Flow valves are now widely used all over the world, in Shangrila Hotel, Kerry Center, Milan Expo, Fiat Workshop, IKEA, COSCO vessels, etc.
> Marine > HVAC > Water Treatment > Oil & GasAccumulating 10 years' experience in valves, we are an excellent solution provider. Keep in touch now and experience how your needs are well addressed.
> Client Stories > Our Projects > Company News > Industry NewsWith over 10 years of experience in the industry of valves, I-FLOW will provide the perfect solution for your project. Contact us now, we will solve all your problems.
> Download > After-sale Service > FAQsen |
We will contact you within 24 hours.
The range can be engineered to suit your application, with body construction, material, and ancillary features optimised to meet your process needs. Being ISO 9001 certified, we adopt systematic ways to ensure high quality, you can be assured of outstanding reliability and sealing performance through the design life of your asset.
· Water temperature: 0.1℃~30℃ ( 0.1℃~90℃ for hot water)
· Water pressure: ≤1Mpa (1.6MPa for special requirement)
· Note:For hot water,the Model:LXLCR-50~300
LXLC(R)-50~300
Removable element woltman water meter
This meter can be used for a remote reading transmission system as equipped with a built-in sensor.
Application
--Measuring the volume of water passing through the pipeline.
Feature:
--Removable element structure, easy installation and maintenance, register for universal use within this range detachable without Removing the meter from the pipeline;
--Dry-dial, Magnetic drive sensitive action, negligent pressure loss;
--Vacuum sealed register to keep the reading clear in a long term service;
--Selected high quality materials for steady & reliable characteristic;
--Manufactured and tested in accordance to standard ISO 4064.
.
Working condition
Water temperature:
Water pressure: ≤1Mpa (1.6MPa for special requirement)
Note:For hot water,the Model: LXLCR-50~300
Maximum permissible errors
1. in the lower zone from qmin inclusive up to but excluding qt is ±5%
2. in the upper zone from qt inclusive up to and including qs is ±2% (±3% for hot water meter)
Model | Size (mm) | Class | qs | qp | qt |
qmin | Min. Reading | Max. | ||
Nomal register | M type register | Nomal register | M type register | |||||||
m3/h | m3 | |||||||||
LXLC(R)-50 | 50 | A | 30 | 15 | 4.5 | 1.2 | 0.0005 | 0.0002 | 999,999 | 999,999 |
B | 3.0 | 0.45 | ||||||||
LXLC(R)-65 | 65 | A | 50 | 25 | 7.5 | 2.0 | 0.0005 | 0.0002 | 999,999 | 999,999 |
B | 5 | 0.75 | ||||||||
LXLC(R)-80 | 80 | A | 80 | 40 | 12 | 3.2 | 0.002 | 0.002 | 999,999 | 9,999,999 |
B | 8.0 | 1.2 | ||||||||
LXLC(R)-100 | 100 | A | 120 | 60 | 18 | 4.8 | 0.002 | 0.002 | 999,999 | 9,999,999 |
B | 12 | 1.8 | ||||||||
LXLC(R)-125 | 125 | A | 200 | 100 | 30 | 8 | 0.002 | 0.002 | 999,999 | 9,999,999 |
B | 20 | 3 | ||||||||
LXLC(R)-150 | 150 | A | 300 | 150 | 45 | 12 | 0.002 | 0.002 | 999,999 | 9,999,999 |
B | 30 | 4.5 | ||||||||
LXLC(R)-200 | 200 | A | 500 | 250 | 75 | 20 | 0.002 | 0.002 | 999,999 | 9,999,999 |
B | 50 | 7.5 | ||||||||
LXLC(R)-250 | 250 | A | 800 | 400 | 120 | 32 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
B | 80 | 12 | ||||||||
LXLC(R)-300 | 300 | A | 1200 | 600 | 180 | 48 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
B | 120 | 18 |
Dimensions data(mm)
Model | Size |
L
|
H
| Flange connection | |||||
φD1 External diameter | φD2 Bolt circle diameter | Connecting Bolts (n-M) | |||||||
mm | |||||||||
LXLC(R)-50 | 50 | 200 | 261 | 165 | 125 | 4-M16 | |||
LXLC(R)-65 | 65 | 200 | 271 | 185 | 145 | 4-M16 | |||
LXLC(R)-80 | 80 | 225 | 279 | 200 | 160 | 8-M16 | |||
LXLC(R)-100 | 100 | 250 | 289 | 220 | 180 | 8-M16 | |||
LXLC(R)-125 | 125 | 250 | 299 | 250 | 210 | 8-M16 | |||
LXLC(R)-150 | 150 | 300 | 319 | 285 | 240 | 8-M20 | |||
LXLC(R)-200 | 200 | 350 | 346 | 340 | 295 | 8-M20(1.0MPa) | |||
12-M20(1.6MPa) | |||||||||
LXLC(R)-250 | 250 | 450 | 450 | 395(1.0MPa) | 350(1.0MPa) | 12-M20(1.0MPa) | |||
405(1.6MPa) | 355(1.6MPa) | 12-M24(1.6MPa) | |||||||
LXLC(R)-300 | 300 | 500 | 478 | 445(1.0MPa) | 400(1.0MPa) | 12-M20(1.0MPa) | |||
460(1.6MPa) | 410(1.6MPa) | 12-M24(1.6MPa) |